base/protocols/modbus/main.zeek¶
- Modbus¶
Base Modbus analysis script.
- Namespace
Modbus
- Imports
Summary¶
Types¶
Redefinitions¶
|
|
Events¶
Event that can be handled to access the Modbus record as it is sent on to the logging framework. |
Hooks¶
Detailed Interface¶
Types¶
- Modbus::Info¶
- Type
-
- ts:
time
&log
Time of the request.
- uid:
string
&log
Unique identifier for the connection.
- id:
conn_id
&log
Identifier for the connection.
- func:
string
&log
&optional
The name of the function message that was sent.
- exception:
string
&log
&optional
The exception if the response was a failure.
- track_address:
count
&default
=0
&optional
(present if policy/protocols/modbus/track-memmap.zeek is loaded)
- ts:
Events¶
- Modbus::log_modbus¶
- Type
event
(rec:Modbus::Info
)